Schedule a meeting Request a demo MCS Online Shop
Headstage to record data from one 60-electrode MEA with small footprint and operatable in a humid incubator.
Headstage to record data from one 120-electrode MEA with small footprint and operatable in a humid incubator.
Perfusion kit for MEA-Systems including TC02, PH01, PPS2, and 2 MPH.
Interface board with signal processor for real-time signal detection and feedback.
Interface board with signal processor for real-time signal detection and feedback. Receives data from MEA2100-Headstages, Multiwell-MEA-Headstage, CMOS-MEA5000-Headstage, ME2100-Systems or W2100-Systems.
MCS signal collector unit for MEA2100-Mini-System or MEA2100-Beta-Screen-System.
Peristaltic perfusion system PPS2 with 2 independent pumps.
Heatable perfusion cannula with temperature sensor; temperature can be programmed with the temperature controller TC01 or TC02.
Constant Vacuum Pump with pressure control.
Magnetic perfusion holder for perfusion cannula.
Temperature Controller, 2 channels.
Video microscope table with one video microscope underneath. Images the electrode field of a microelectrode array (MEA) in an amplifier placed on top of the table and transfers the image via USB 3.0 to a computer. Suitable for all MCS MEA systems (MEAÂ Mini, MEAÂ 256, MEAÂ Lite).
Optical stimulator for MEA2100-HS60/120/256
60 channel impedance testing device for microelectrode arrays to identify the quality of MEAs and monitor the development of the impedance of each electrode over the entire life span of the array. Compatible with MEAs with 60 electrodes.
Signal generator for MEA2100-Systems: Can be placed in MEA2100-HS(2x)60. Simulates 12 different types of sine curves and biological signals.
Test model probe with CB-GND cable (for ground connection). For all MEA1060 amplifiers and MEA2100-HS(2x)60.
Climate chamber for MEA2100-Systems. Covers the MEA to create a 5 % CO2 atmosphere (humid or non-humid) around the biological probe. Connects magnetically to the MEA2100-headstage.
• Heating element with Pt100 sensor, spare part for MEA2100-Mini-HS60/-HS120. • Bore hole size: 8 mm
• Heating element with Pt100 sensor, spare part for MEA2100-Mini-HS60/-HS120. • Bore hole size: 25 mm
Perfusion element to use perforated MEAs (pMEA) together with MEA2100-Mini-headstage.
Gold spring contacts for MEA2100-headstages, 10 pieces. Suitable for MEA2100-HS60/HS2x60/HS120.
Cable for connection of TC01/02 to MEA2100-HS, or to PH01
1 Ag/AgCl-pellet for grounding the bath
Cable connecting the internal reference electrode of a test model probe or signal generator for a MEA to ground
Cable with one Lemo and one BNC connector, 1m.
Cable connecting MCS signal collector unit OPTO-STIM output to 4x BNC-plugs